High Energy Spark Igniter D-HG 400 高压点火器 |
Download the D-HG 400 Brochure
(Adobe.pdf file; 0.8MB) |
D-HG400型
* 用于点燃大功率工业燃烧装置的液态或气态燃料
* 点火棒与控制器为一个整体
* 按需要可提供具有防爆性能的、点火棒独立式点火器
* D-VE500型自动点火推进装置 |
Combustion Automation Units and Flame Monitors
D-GF 55, D-UV 55-10, D-IR 55-10, D-IO 55-10 |
Download the 55 Series Brochure
(Adobe.pdf file; 0.8MB) |
-
For intermittent operation
-
Low cost combustion automation units and flame monitors without self-check
-
Regulation and Monitoring of oil- and gas-burners with intermittent operation
-
Simple Installation
-
No adjustments required
- Meets the requirements of UL 372 and FM Class 7610
|
All-In-One Flame Scanner D-LX 100 |
View the Expanded Specifications
Download the LX 100 Brochure
(Adobe.pdf file; 0.8MB) |
-
Main application at industrial single burners with continuous or intermittent operation, e.g. in chemical industries, refineries or cement plants
-
New semiconductor technology with highest sensitivity replaces UV tube for UV flame detection
-
Compact design, flame scanner and amplifier built as one unit, therefore, no space is needed inside a cabinet
-
Self-checking and failsafe according to UL 372, FM 7610 as well as EN 230 and EN 298
- Housing meets NEMA 4x (IP 67).
-
Relay output contact for direct control of the fuel valve and for status display
-
Programmable flame recognition threshold
-
Analog output for flame intensity
0/4 - 20 mA
- Fulfills EMC guidelines IEC 555 and IEC 1000 as well as EN 50 081 and EN 50 082
|
Flame Sensors D-LE 100/101 and D-LE 600/601 |
Download the LE 100/101/600/601 Brochure
(Adobe.pdf file; 0.6MB) |
|
Flame Scanner Control System D-UG 660 |
Download the D-UG 660 Brochure
(Adobe.pdf file; 0.4MB) |
-
Monitoring of flames in the UV and IR range (depending on the flame scanner of the series D-LE 100/D-LE 101 or D-LE 600/D-LE601)
-
Sensitivity adjustable in 3 ranges and 100 steps
- Flame intensity displayed in percent
-
Pulse frequency indication for flame stability monitoring
- T躒 approved for oil/gas continuous operation for 72 operating hours without capacity limitations
- UL and FM listed
|
Flame Sensor D-LE 701/703 with
Fiber Optic System D-LL 702/703/704 |
|
-
Optical flame sensor with fiber optics for various spectral ranges, from UV to IR
- Typical applications include:
-
Can be used in conjunction with the D-UG 110/120/660 controllers and D-GF 100/200 combustion automation unit
-
Uniform output signal thus mutually interchangeable
-
Can be adjusted for different combustion conditions, e.g., flue
gas recirculation
- Corresponds to current American and European safety requirements for flame monitoring equipment
|